Looking for:
M11 autoclave manualM11 autoclave manual -
Adequate space must be maintained around all items placed in the chamber to assure proper steam circulation and adequate drying. The charts below are provided as a reference regarding the maximum loads that can be processed in the sterilizers but maintaining proper spacing between all items processed to assure good steam circulation and drying should be the guiding factor in determining the maximum load that can be processed.
Lift the door handle, then push the door closed. While pushing in on the door, slide the door handle down to engage the latch. Consult instrument manufacturer for specific sterilization instructions.
A Press the appropriate cycle button on the display panel. After the cycle button is pressed, the parameters for that cycle will appear on the display. The chart below illustrates the display messages that will appear during each stage of the cycle.
Qualified personnel responsible for infection control should prepare a protocol for handling sterilized items. This protocol should be followed by all personnel responsible for handling sterilized items.
Cycle buttons 1 and 2 can be used for custom applications that are not covered by standard cycle programs. These cycles have not been FDA cleared for medical use. The programmable cycles allow the user to adjust cycle parameters in order to sterilize items that cannot be sterilized in any of the standard pre-programmed cycles.
Once a custom program has been stored, it can be used just by pushing the 1 or 2 button. If you wish to change the settings, these buttons may be reprogrammed at any time. If you have any questions about this procedure or any other Midmark M11 Tech Issues please contact us and let us help. Take the guesswork and worrying about what unit is due for maintenance and which maintenance cycle it is time for.
The Midmark M11 autoclave is available here. Biological Indicators are available here. Chemical Indicators are available here. Your email address will not be published. Equipment Alert Use distilled water or water that meets the referenced water purity specifications.
Qualification Testing Your sterilizer should be tested after sterilizer installation, malfunctions, relocation, major repairs, being turned off or shut down for more than three days and after sterilization process failure.
Types of Items that can be processed in the M11 Before placing any instrument in the M11, check with the instrument manufacturer to be sure the materials are compatible with steam sterilization and to verify the acceptability of sterilization parameters. CSR wrap, instrument pouches, etc.
Corrosion sensitive metal ex. The use of automated cleaning equipment e. Cleaning Autoclave cleaning instructions. Distilled water is required by your autoclave. This removes all impurities that could be transmitted to your tools. When you choose a Midmark sterilizer, protect your investment by purchasing through a Midmark-authorized dental distributor. Midmark sterilizers are carefully inspected and certified, and our authorized dental distributors are uniquely qualified to install and service them so that you have the best possible experience.
Be sure about your purchase. Thank you for choosing Midmark. Note: Medical and Animal Health authorized distributors will vary. Share this Page. Steam Sterilizers. Images Donate icon An illustration of a heart shape Donate Ellipses icon An illustration of text ellipses. Metropolitan Museum Cleveland Museum of Art. Internet Arcade Console Living Room. Books to Borrow Open Library. Search the Wayback Machine Search icon An illustration of a magnifying glass.